The Coulter Principle (1954-1955)
While under contract to the United States Navy in the late 1940s, Wallace H. Coulter developed a technology for counting and sizing particles using impedance measurements. The technology was principally developed to count blood cells quickly by measuring the changes in electrical conductance as cells suspended in a conductive fluid passed through a small orifice. Presently, over 98% of automated cell counters incorporate this technology, which is referred to as the Coulter Principle. In the past seventy-five years, the technology has also been used to characterize thousands of different industrial particulate materials.
Beckman Coulter instrument systems which utilize this principle are called COULTER COUNTER instruments. Drugs, pigments, fillers, toners, foods, abrasives, explosives, clay, minerals, construction materials, coating materials, metals, filter materials, and many other sample types have all been analyzed using the Coulter Principle. This method can be used to measure any particulate material that can be suspended in an electrolyte solution. Particles as small as 0.4 µm and as large as 1600 µm in diameter can routinely be measured. Over 8,000 references to the uses of this technology have been documented.
In a COULTER COUNTER instrument, a tube with a small aperture on the wall is immersed into a beaker that contains particles suspended in a low-concentration electrolyte. Two electrodes, one inside the aperture tube and one outside the tube but inside the beaker, are placed and a current path is provided by the electrolyte when an electric field is applied (Figure 1). The impedance between the electrodes is then measured. The aperture creates what is called a "sensing zone". Particles in low concentration, suspended in the electrolyte, can be counted by passing them through the aperture. As a particle passes through the aperture, a volume of electrolyte equivalent to the immersed volume of the particle is displaced from the sensing zone. This causes a short-term change in the impedance across the aperture. This change can be measured as a voltage pulse or a current pulse. The pulse height is proportional to the volume of the sensed particle. If constant particle density is assumed, the pulse height is also proportional to the particle mass. This technology is also referred to as aperture technology.
Using count- and pulse-height analyzer circuits, the number and volume of each particle passing through the aperture can be measured. If the volume of liquid passing through the aperture can be precisely controlled and measured, the sample concentration can also be determined. In modern COULTER COUNTER instruments, such as the Multisizer™ 3 and 4, particle counter and sizing instruments, pulses are digitized and saved with several key parameters that describe each pulse such as pulse height, pulse width, time stamp, pulse area, etc. These parameters enable the instrument to better discriminate between noise and real pulses as well as between normal and distorted pulses due to various reasons when particles pass through the aperture. Saved pulses can be used to monitor sample changes over the measurement time period should pulses be arranged in time sequence. In practice, particle volume is often represented in terms of equivalent spherical diameter. The measured particle volume (or size) can be then used to obtain particle size distribution.
With counting and sizing rates of up to 10,000 particles per second, it takes less than one minute to perform a typical measurement with a COULTER COUNTER instrument. The accuracy of size measurements can be better than 1%. Aperture size typically ranges from 20-2000 µm. Each aperture can be used to measure particles within a size range of 2 to 80% of nominal diameter. Therefore, an overall particle size-range of 0.4-1600 µm is feasible. However, the ability of the technology to analyze particles is limited to those particles that can be suitably suspended in an electrolyte solution. The upper limit therefore may be 500 µm for sand but only 75 µm for tungsten carbide particles. Moreover, the lower size limit is restricted by electronic noise generated mainly within the aperture itself. The selection of the most suitable aperture size is dependent upon the particles to be measured. If the sample to be measured is composed of particles largely within a 30:1 diameter size range, the most suitable aperture can be chosen. For example, a 30 µm aperture can measure particles from about 0.6 to 18 µm in diameter. A 140 µm aperture can measure particles from about 2.8 to 84 µm. If the particles to be measured cover a wider range than a single aperture can measure, two or more apertures must be used and the test results can be overlapped to provide a complete particle size distribution.
Highest Resolution for Particle Size Analysis
During the Coulter Principle measurement, as a particle passes through the sensing zone when the liquid is drawn from the container, a volume of the electrolyte equivalent to the immersed volume of the particle is displaced from the sensing zone. This causes a short-term change in the resistance across the aperture. This resistance change can be measured either as a voltage or current pulse. By measuring the number of pulses and their amplitudes, one can obtain information about the number of particles and the volume of each individual particle.
The number of pulses detected during measurement is the number of particles measured, and the amplitude of the pulse is proportional to the volume of the particle. Because this is a single-particle measurement process, it yields the highest resolution that any particle characterization technique can achieve. The particle diameter can be determined at the resolution of voltage or current measurement which can be very accurately using current electronics technology. The distribution amplitude can be determined to the accuracy of a single particle.
The advantages of such high resolution are multiple with the most obvious being the capability to display details of a particle size distribution. In a particle size distribution measurement, typically each distribution, whether displayed cumulatively or differentially, is composed of a few-hundred data points in a pre-set size range. Each data point is called a bin. Since every particle is measured, each bin is a collection of particles in a given size range. Depending on the distribution broadness, the total size range can be reset to a finer division, therefore showing the distribution details (i.e., each bin can be pre-set to cover a smaller size range).
Other advantages include fine differential between two particles and more accurate statistic values calculated from the distribution. The figures below show a sample measured using the Beckman Coulter Multisizer 4 and displayed in different size ranges. The pulse data was resorted into a finer set of bins in the right figure in which more detail of the distribution is displayed.
Digital Pulse Process
In Coulter Principle instrumentation, the change in electric resistance due to passages of particles through the aperture is determined using fast electronic circuitry. Detected signals are instantaneously digitized at a rate of a few-million times per second into digital signals. The digital signal is then recorded for every pulse in the form of pulse parameters (i.e., timing, height, width of pulses, etc.). As most measurements seek to obtain particle counting or size distribution, the recorded pulse height is converted to particle size using the calibration constant and placed into one of the pre-set size bins. Particle size distribution and counting are the cumulative result of all pulses measured. All recorded pulse parameters are still available for purposes other than standard, full-range particle size distribution. These parameters can be subtracted or sorted (i.e., reprocessed differently based on specific applications). For example, if an operator seeks to have a zoom-in size distribution showing every detail of the distribution, then a narrower size range can be selected and all pulses can be sorted and placed into the new set of finer bins. Another example is found when pulse heights (or sizes) are sorted in a time sequence (for samples of narrow size-distribution) t monitor sample change during measurement. Still another example is using one plot pulse height as a function of pulse width to find information of particle shape.
As a particle passes through the aperture, it creates a resistance. The bigger the particle, the more the resistance, the greater the voltage. Each voltage spike is directly proportional to the size of the cell. Today every modern hematology analyzer depends in some way on the Coulter Principle.

Coulter Counter Model F
A method was devised for using the model F Coulter Counter for counting goat erythrocytes, which are smaller and more numerous than those of humans. Blood samples were taken from 25 goats, and the cells were counted using 100- and 70-micron aperature tubes. A visual count also was made of a portion of each sample. The results were analyzed statistically to determine which aperture would produce the most accurate and reproducible results when compared with the manual counts. It was found that counts obtained with the 100-micron aperature tube were not significantly different from the manual counts.
This technology found commercial success in the medical industry where it revolutionized the science of hematology. Red blood cells, white blood cells and platelets make up the majority of the formed elements in the blood. When whole anticoagulated human blood is diluted with isotonic saline, the Coulter principle can be applied to count and size the various cells that make up whole blood. The first commercial application of the Coulter principle to hematology came in 1954 with the release of the Coulter Counter Model A (developed by Wallace and brother Joseph R. Coulter.
Within a decade, literally every hospital laboratory in the United States had Coulter Counter, and today every modern hematology analyzer depends in some way on the Coulter Principle.
Explore Different Instruments within Our Portfolio
We offer a wide variety of instruments for total optimization of your laboratory. Our focus on innovation, reliability and efficiency has led us to become the partner of choice for clinical, research and industrial customers around the globe.
Centrifuges
Our centrifuge portfolio ranges from the Microfuge line and larger, high-performance benchtop models to floor-model ultracentrifuges, and analytical ultracentrifugation (AUC) instruments.Flow Cytometers
We offer research and clinical models that take the best of legacy flow cytometers and set a new standard for more compact, more versatile and more powerful instruments.Liquid Handlers
A variety of configurations allows you to optimize performance and reduce hands-on time for most genomic, drug discovery and basic research application workflows.Cell Analyzers
The COULTER COUNTER Analyzers provide size distribution in number, volume and surface area in one measurement, with an overall sizing range of 0.4 µm to 1600 µm.Explore Additional Topics, Research, Standards, Documents, Videos and More
-
База знаний Beckman Coulter Life Sciences
-
Научные направления
-
Иммунотерапия
- Об иммунотерапии
- О вирусных векторах
- Future of Pediatric
- Manufacturing Processes for Engineered T-Cell Therapy – CAR-T
- Исследования в иммунотерапии: Оборудование
- Новые перспективы в иммунотерапии онкозаболеваний
- Характеризация вирусных векторов: анализ гомогенности rAAV
- Разработка и получение вирусных векторов: будущее генной терапии
- Antibody Engineering
- Process Development
- Small-Molecule Drug Discovery and Development
- CAR-T-клетки: Иммунотерапия опухолей
- Технология CRISPR в иммунотерапии
-
Иммунотерапия
- Научные основы
- Disease Management
-
Biologics Drug Discovery and Development
- Analytical Method Development and Testing
- Biologics Assay Development
- Introduction to Biologics
- Target Discovery, Identification and Selection
- Biologics Drug Discovery
- Preclinical Drug Development
- Flow Cytometry in Cell Therapy
- Biologics Upstream Development
- Biologics Downstream Development
- cGMP Biologics Production
- QA / QC Release Testing
-
Disease Research
- Allergies
- Autoimmune Diseases
- Cardiovascular Disease
- Immune-Mediated Inflammatory Diseases
- Infectious Diseases
- Metabolic
- Diseases of the Microbiome
- Oncology
- Congenital Disorders
- Dermatological Diseases
- Environmental Diseases
- Gastrointestinal Diseases & Disorders
- Genetic
-
Leukemia and Lymphoma
- B Cell Malignancies
- Minimizing Waste in Flow Cytometry Workflows
- T Cell Malignancies
- Myeloid Malignancies
- CD200 Expression in B-lineage Neoplasms
- Importance of CD34 in Screening Tests for Hematolymphoid Neoplasms: ClearLLab LS Shows the Way
- Utilization of the ClearLLab lymphoid screening tube for investigation of hematolymphoid neoplasias by flow cytometry
- Demonstration of the Clinical Performance of the ClearLLab LS in a Multi-Center Study
- Performance Testing of the ClearLLab LS (Lymphoid Screen)*
- Standardized Compensation Setup for the ClearLLab 10C Application
- ClearLLab Control Cells – a Process Control for ClearLLab 10C Application
- Download the Immunophenotyping Reference Table for Hematopoietic Malignancies
- ClearLLab 10-Color Panel Performance: Lot-to-Lot Reproducibility
- ClearLLab 10C Panel Markers and how they are combined
- Standardized reagents and guidelines for the immunophenotyping of hematologic neoplasms by flow cytometry
- DURA Innovations Cost Benefit Calculator
- Leukemia and lymphoma: an example of how flow cytometry aids diagnosis
- Workflow Efficiency from Using Dry Reagents
- Dry Versus Liquid Antibody Reagents
- Meet the Experts
- Standardized Results - Clinical Vignettes
- Global Health
- Future of Bioprocessing
-
Индустрия
- Synthetic Biology
- Biomanufacturing
- Химические реагенты и материалы
- Clinical Lab
- Контрактные исследовательские организации
- Продукты питания и напитки
- Фармакологическое и биотехнологическое производство
- Public-Private Partnerships
- Hydraulics Heavy Machinery
- Military
- US National Institute of Health (NIH) Grants and Funding
- Академические и правительственные исследования
-
Отраслевые стандарты
- USP<643>
-
21 CFR Part 11 - Data Integrity
- 21 CFR Part 11 Related Products: Instruments for Data Integrity and Compliance
- 21 CFR Part 11: Scope and Application
- Centrifugation That Supports 21 CFR Part 11 Compliance
- Глобальные эквиваленты и соответствующие правила
- УЛУЧШЕНИЕ ЦЕЛОСТНОСТИ ЭЛЕКТРОННЫХ ДОКУМЕНТОВ
- 21 CFR Part 11 - Terms and Acronyms
- Maintaining Data Integrity: Understanding ALCOA Guidance
- European Pharmacopoeia EP 2.2.44
- EU GMP Annex 1
- EU GMP Annex 11
- ISO 21501
- ISO Regulations
-
IVD-Regulation (IVDR)
- IVDR compliant instruments*
- IVDR compliant software*
- IVDR compliant reagents
- E-book
- Future proofing your flow cytometry panel under IVDR
- In-house IVD FCM panel or not: it depends
- Building IVDR compliant panels for haematological disorders
- Impact of the new EU IVD-Regulation on the daily life of the clinical Flow cytometry laboratory webinar
- Laboratory Developed Test (LDT) vs IVD Validation Workflow
- Meet the Expert — Maurizio Suppo, PhD
- Potential Impacts of EU IVD-Regulation on the Clinical Flow Cytometry Lab
- IVD-R Annex I Global Safety and Performances Requirements (GSPR). A New Set of Requirements for Clinical Laboratories Performing Laboratory Developed Tests
- IVD-R: Key Considerations to Validate a Flow Cytometry Assay According to ISO 15189 Requirements
- Regulatory Entities: Separation with Cooperation
- USP 1046
- USP 1047
- Статьи Фармокопеи США USP 788 и USP 787. Глава Европейской Фармакомпеи EP 2.9.19.
- USP <790>
- Стандарт ISO 11171
-
Чистота воздуха в чистых помещениях и чистых зонах
- Счетчики частиц разработаны в соответствии с требованиями ISO 14644-1 и ISO 21501-4
- ISO 14644: Опубликованные стандарты за 2015 г.
- Классификация чистоты воздуха по концентрации частиц в соответствии со стандартом ISO 14644-1
- ISO 21501-4 Счетчики светорассеивающих частиц в воздухе для чистых помещений
- Подсчет частиц: Термины и формулы
-
USP <787>
- Глава <787> Фарм. США «Тестовые растворы для контроля контаминации
- Метод светоблокировки – оптический метод выявления частиц
- Глава <787> Фармакопеи США «Невидимые невооруженным глазом механические включения в белковых лекарственных препаратах для инъекций» (USP <787>)
- USP <787>: Application and Scope
- Требования к чистым помещениям для определения количества частиц в жидкостях
- Методы и инструменты
-
Explore Resources For Your Sample Type
- Biomolecules
- Body Fluids
- Cell Organelles
-
Extracellular Vesicles
- Exosomes
- Apoptotic Bodies
- History of EV
- Deciphering Heterogeneity of EVs
- EV Sample Preparation Characterization
- Into the world of EVs
- Nanoscale Flow Cytometry
- Ectosomes
- Extracellular Vesicles Workflow
- Getting Started with Extracellular Vesicles
- Liposomes
- Micelles
- Microsomes
- Overview
- Polymer Coatings
- Lipid Nanoparticle Characterization
- Tissues
- Исследования наночастиц
-
Технологии
-
Machine Learning Assisted Analysis for Cytometry Data
- Application Programming Interface (API)
- Snapshot of the Workflow for High Dimensional Data Analysis: from Start to Publication
- Customer Interview: Jamie D. McNicol, Analytical Project Manager
- Data Expectations
- How Does the Cytobank Workflow Fit Your Research?
- Learn from your peers
- Advance Your Knowledge of Machine Learning-Assisted Analysis
- Get the Cytobank Platform and Publish
- Reproducible High Dimensional Data Analysis: Is Your Lab Ready?
- Untapped Potential
-
Лазерная дифракция и анализ размера частиц
- Теория дифракции света Фраунгофера и теория светорассеяния Ми
- Лазерная дифракции и PIDS для измерения малых и несферических частиц
- sample preparation for singleparticle electron cryomicroscopy
- Технология дифференциальной интенсивности рассеянного поляризованного света (PIDS)
- Анализ размеров пигментных частиц методом лазерной дифракции
- Multimodal Samples with Laser Diffraction
- Next Generation Sequencing
-
Analytical Ultracentrifugation
- Оптические системы аналитических ультрацентрифуг
- Basics
- Виды экспериментов в аналитическом ультрацентрифугировании
- Antibody Characterization with Analytical Ultracentrifugation
- Protein Characterization
- История изобретения и развития аналитического ультрацентрифугирования (AUC)
- Potential of AUC in biopharma
- Analytical Ultracentrifugation Publications
- Multiwavelength
- DGE-AUC Simply AUC
- Title
- Динамическое рассеяние света
- Dried Reagent Technology
- Accessible Flow
- Acoustic Sample Management
- Elevating Bioprocessing Efficiency with Avanti JXN and Optima XPN Centrifuges
- How the Vi-CELL BLU Analyzer supports You from Data to Insights
-
Научные основы лабораторной автоматизации
- 7 вопросов, на которые следует ответить перед покупкой автоматизированной лабораторной станции для дозирования жидкостей
- Внедрение автоматизации в вашей лаборатории
- Applications in synthetic biology automation
- beckman biomek i3 automated magnetic bead cleanup
- echo dbtl high throughput dna assembly
- echo fastpb high throughput gene construction
- beckman echo525 high throughput plating
- biomek-i3-automated-cell-transfection-doe
- biomek i3 introduction
- echo drug sensitivity resistance screening
- high-throughput-anaerobic-fermentation-probiotics-biolector-xt
-
Метод центрифугирования
- Биобезопасность в лаборатории при центрифугировании
- sample preparation for singleparticle electron cryomicroscopy
- Analytical ultracentrifugation technique: Quantitative analysis of crude AAV samples using DGE AUC
- exosome-ultracentrifugation-rotor-tube-selection
- Continuous Flow Centrifugation
- Dynamic Rotor Inertia Check
- Elutriation Centrifugation
- JP High Performance Ecosystem
- Safety Seminar
- Ultra Harmonic Technology (UHT)
- An Introduction to Ultracentrifugation
- Dr Beckman
- JP DGUC Solution
- Density Gradient Centrifugation
- Принципы метода центрифугирования
- Cytobank Training
- SPRI Beads
- Accessible Flow Learning Center
- Flow Cytometry Basics
- Flow Cytometry Data Reproducibility
- Flow Cytometry Panel Design
-
The Coulter Principle
- Detect bacterial contamination in algae cultures with the Beckman Coulter Multisizer 4e Kurt counter
- beckman biolector multisizer cell monitoring analysis
- China yeast process development
- Coulter Counter for Industrial field
- Coulter Counter for Life Science Research
- Coulter Principle Short Course - Chapter 1
- Coulter Principle Short Course - Chapter 2
- Laser vs Coulter Counter
-
Machine Learning Assisted Analysis for Cytometry Data
-
Материалы для чтения
-
Указания по применению
- 17-Marker, 18-Color Human Blood Phenotyping Made Easy with Flow Cytometry
- 21 CFR Part 11 Data Integrity for On-line WFI Instruments
- 8011+ Reporting Standards Feature and Synopsis
- Air Particle Monitoring ISO 21501-4 Impact
- Automated Cord Blood Cell Viability and Concentration Measurements Using the Vi‑CELL XR
- Biomek Automated NGS Solutions Accelerate Genomic Research
- Biomek i-Series Automation of the Beckman Coulter GenFind V3 Blood and Serum DNA Isolation Kit
- Preparation and purification of carbon nanotubes using an ultracentrifuge and automatic dispensing apparatus, and analysis using an analytical centrifuge system
- Viability Assessment of Cell Cultures Using the CytoFLEX
- Classifying a Small Cleanroom using the MET ONE HHPC 6+
- Clean Cabinet Air Particle Evaluation
- Recommended cleaning procedure for the exterior surface of the MET ONE 3400+
- Counting Efficiency: MET ONE Air Particle Counters and Compliance to ISO-21501
- Critical Particle Size Distribution for Cement using Laser Diffraction
- Detecting and counting bacteria with the CytoFLEX research flow cytometer: II-Characterization of a variety of gram-positive bacteria
- Efficient kit-free nucleic acid isolation uses a combination of precipitation and centrifugation separation methods
- Echo System-Enhanced SMART-Seq v2 for RNA Sequencing
- Grading of nanocellulose using a centrifuge
- Grading of pigment ink and measurement of particle diameter using ultracentrifugation / dynamic light scattering
- How to Use Violet Laser Side Scatter Detect Nanoparticle
- HRLD Recommended Volume Setting
- Particle Size Analysis Simple, Effective and Precise
- Flow Cytometric Analysis of auto-fluorescent cells found in the marine demosponge Clathria prolifera
- MET ONE Sensor Verification
- Metal colloid purification and concentration using ultracentrifugation
- Разделение наночастиц золота в градиенте плотности с использованием центрифуги Avanti JXN и бакетного ротора JS-24.15
- Miniaturized and High-Throughput Metabolic Stability Assay Enabled by the Echo Liquid Handler
- Minimal Sample to Sample Carry Over with the HIAC 8011+
- Modern Trends in Non‐Viable Particle Monitoring during Aseptic Processing
- Particle diameter measurement of a nanoparticle composite - Using density gradient ultracentrifugation and dynamic light scattering
- Identification of Circulating Myeloid Cell Populations in NLRP3 Null Mice
- Optimizing the HIAC 8011+ Particle Counter for Analyzing Viscous Fluids
- Particle testing in cleanroom high-pressure gas lines to ISO 14644 made easy with the MET ONE 3400 gas calibrations
- Pharma Manufacturing Environmental Monitoring
- Pharma Manufacturing Paperless Monitoring
- Analysis of plant genome sizes using flow cytometry: a case study demonstrating dynamic range and measurement linearity
- Calibrating the QbD1200 TOC Analyzer
- Detection Limit
- Vibrio Natriegens Process Scale-up
- A fully automated plate-based optimization of fed-batch culture conditions for monoclonal antibody-producing CHO cell line
- A Deeper Look at Lipid Nanoparticles
- A High-Throughput, Automated Screening Platform for IgG Quantification During Drug Discovery and Development
- Automated Research Flow Cytometry Workflow Using DURA Innovations Dry Reagent Technology with the *Biomek i7 Automated Workstation and *CytoFLEX LX Flow Cytometer
- Automating antibody titration using a CytoFLEX LX analyzer Integrated with a Biomek i7 Multichannel workstation and Cytobank streamlined data analysis
- Automated IDT Alt-R CRISPR/Cas9 Ribonucleoprotein Lipofection Using the Biomek i7 Hybrid Automated Workstation
- Monitoring Yeast Cultures with the BioLector and Multisizer 4e instruments
- Cultivation of suspended plant cells in the BioLector®
- Determination of cell death in the BioLector Microbioreactor
- Echo System-Enhanced SMART-Seq v4 for RNA Sequencing
- A Simple Guide to Selecting the Right Handheld Particle Counter for Monitoring Controlled Environments
- Linearity of the Vi-CELL BLU Cell Counter and Analyzer
- Miniaturized 16S rRNA Amplicon Sequencing with the Echo 525 Liquid Handler for Metagenomic and Microbiome Studies
- mRNA Manufacturing with Fed Batch In Vitro Transcription
- Nanoliter Scale High-Throughput Protein Crystallography Screening with the Echo Liquid Handler
- Optimizing EV Analysis with a CytoFLEX nano flow cytometer and FCMPASS
- Preparation of Mouse Plasma Microsamples for LC-MS/MS Analysis Using the Echo Liquid Handler
- Robust and High-Throughput SARS-CoV-2 Viral RNA Detection, Research, and Sequencing Using RNAdvance Viral and the OT-2 Platform
- The Valita Aggregation Pure assay: A rapid and accurate alternative for aggregation quantification of purified monoclonal antibodies
- Accurate enumeration of phytoplankton using FCM
- Accurately measures fine bubble size and particle count
- Achieving Compliant Batch Release – Sterile Parenteral Quality Control
- Adaptive Laboratory Evolution of Pseudomonas putida in the RoboLector
- Adjustment of the pH control settings in the BioLector Pro microbioreactor
- Aerobic cultivation of high-oxygen-demanding microorganisms in the BioLector XT microbioreactor
- Comparative Analysis of DURAClone IM T-Cell Subsets Antibody Panel: Conventional vs. Spectral Flow Cytometry on CytoFLEX mosaic Spectral Detection Module
- Революция в аналитическом ультрацентрифугировании: новая центрифуга Optima AUC
- CytoFLEX mosaic Spectral Detection Module Enables Enhanced Spectral Unmixing of White Blood Cell Populations by Extracting Multiple Autofluorescence Signatures
- Investigating the murine hepatic immune composition in diet-induced obesity using OMIP-104: Transferring an existing OMIP panel onto the CytoFLEX mosaic Spectral Detection Module
- Analyzing Mussel/Mollusk Propagation using the Multisizer 4e Coulter Counter
- Assay Assembly for Miniaturized Quantitative PCR in a 384-well Format Using the Echo Liquid Handler
- Automated 3D Cell Culture and Screening by Imaging and Flow Cytometry
- Automating a Linear Density Gradient for Purification of a Protein:Ligand Complex
- Automating Biopharma Quality Control to Reduce Costs and Improve Data Integrity
- Automating Bradford Assays
- Automating Cell-Based Processes
- Automating Cell Line Development
- Anaerobic cultivation processes of probiotic bacteria in the BioLector XT microbioreactor
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Automation of CyQuant LDH Cytotoxicity Assay using Biomek i7 Hybrid Automated Workstation to Monitor Cell Health
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Automation of protein A ELISA Assays using Biomek i7 hybrid workstation
- Новая центрифуга Avanti J-15 повышает сохранность и максимизирует выход образцов
- Новый режим торможения в центрифуге Avanti J-15 экономит время и повышает эффективность работы
- Комплексное решение для очистки белков с центрифугой Avanti JXN
- Avoid the Pitfalls When Automating Cell Viability Counting for Biopharmaceutical Quality Control
- Basics of Multicolor Flow Cytometry
- Beer, Evaluation of Final Product and Filtration Efficiency
- Monitoring E. coli Cultures with the BioLector and Multisizer 4e Instruments
- Biomek Automated Genomic Sample Prep Accelerates Research
- Biomek i7 Hybrid Automated KAPA mRNA HyperPrep Workflow
- Biomek i-Series Automated AmpliSeq for Illumina® Library Prep Kit
- Biomek i-Series Automated Beckman Coulter Agencourt RNAdvance Blood Kit
- Biomek i-Series Automated Beckman Coulter Agencourt RNAdvance Cell
- Biomek i-Series Automated Beckman Coulter Agencourt SPRIselect for DNA Size Selection
- Biomek i-Series Automated IDT® xGen Hybridization Capture of DNA libraries on Biomek i7 Hybrid Genomics Workstation
- Biomek i-Series Automated Illumina Nextera DNA Flex Library Prep Kit
- Biomek i-Series Automated Illumina® Nextera XT DNA Library Prep Kit
- Biomek i-Series Automated Illumina TruSeq DNA PCR-Free Library Prep Kit
- Biomek i-Series Automated Illumina TruSeq® Nano DNA Library Prep Kit
- Biomek i-Series Automated Illumina TruSeq® Stranded mRNA Sample Preparation Kit Protocol
- Biomek i-Series Automated Illumina TruSeq® Stranded Total RNA Sample Preparation Kit Protocol
- Biomek i–Series Automated Illumina® TruSight Tumor 170 32 Sample Method
- Biomek i-Series Automated KAPA HyperPrep and HyperPlus Workflows
- Biomek i-Series Automated New England Biolabs NEBNext® Ultra II DNA Library Prep Kit
- Biomek i-Series Automated SurePlex PCR and VeriSeq PGS Library Prep for Illumina
- Biomek i-Series Automation of the DNAdvance Genomic DNA Isolation Kit
- Cell Counting Performance of Vi–Cell BLU Cell Viability Analyzer
- Cell Line Development – Data Handling
- Cell Line Development – Limiting Dilution
- Cell Line Development – Selection and Enrichment
- Cellular Analysis using the Coulter Principle
- Changes to GMP Force Cleanroom Re-Classifications
- Характеризация препаратов инсулина методом аналитического ультрацентрифугирования
- Fda guidance 21 cfr compliance guide for met one 3400 plus
- Cluster Count Analysis and Sample Preparation Considerations for the Vi-CELL BLU Cell Viability Analyzer
- Comparing Data Quality & Optical Resolution of the Next Generation Optima AUC to the Proven ProteomeLab on a Model Protein System
- Conducting the ISO 14644-3 Cleanroom Recovery Test with the MET ONE 3400+
- Considerations of Cell Counting Analysis when using Different Types of Cells
- Consistent Cell Maintenance and Plating through Automation
- Control of Spheroid Size and Support for Productization
- Control Standards and Method Recommendations for the LS 13 320 XR
- Data-integrity-and-met-one-3400-plus-function-for-pharma
- Cydem VT Automated Clone Screening System – Generating an Antibody Standard Curve
- Cydem VT System: A Comparison to Traditional Clone Screening Platforms
- Cydem VT System Analytical Capabilities and Repeatability
- Determination of kLa values on the Cydem VT Automated Clone Screening System
- Optimize Clone Screening: Time Savings with the Cydem VT System in Monoclonal Antibody-Producing Cell Line Development Workflows
- Protein Titer Capabilities - A Comparison of the Cydem VT System to Current Technology across Various CHO Media
- Vi-CELL BLU Analyzer Data Exports and Offline Analysis Instructions
- Use Machine Learning Algorithms to Explore the Potential of Your High Dimensional Flow Cytometry Data Example of a 20–color Panel on CytoFLEX LX
- How to use R to rewrite FCS files with different number of channels
- A new approach to nanoscale flow cytometry with the CytoFLEX nano analyzer
- CytoFLEX nano Flow Cytometer: the new frontier of nanoscale Flow Cytometry
- Detecting Moisture in Hydraulic Fluid, Oil and Fuels
- Detection of Coarse Particles in Silica Causing Cracks in Semiconductor Encapsulants
- Detection of foreign matter in plating solution using Multisizer4e
- Determination of drug-resistant bacteria using Coulter counters
- Determination of Size and Concentration of Particles in Oils
- DO-controlled fed-batch cultivation in the RoboLector®
- dsDNA Quantification with the Echo 525 Liquid Handler for Miniaturized Reaction Volumes, Reduced Sample Input, and Cost Savings
- Screening of yeast-based nutrients for E. coli-based recombinant protein production using the RoboLector Platform
- E. coli fed-batch cultivation using the BioLector® Pro
- Effective Miniaturization of Illumina Nextera XT Library Prep for Multiplexed Whole Genome Sequencing and Microbiome Applications
- Efficient clone screening with increased process control and integrated cell health and titer measurements with the Cydem VT Automated Clone Screening System
- Efficient Factorial Optimization of Transfection Conditions
- Решения для производства и разработки вакцин
- Enumeration And Size Distribution Of Yeast Cells In The Brewing Industry
- Evaluation of Instrument to Instrument Performance of the Vi-CELL BLU Cell Viability Analyzer
- Filling MicroClime Environmental Lids
- Автоматизация иммуноферментного анализа (ИФА) на роботизированной лабораторной станции Biomek i5
- Friction Reduction System High Performance
- Fully Automated Peptide Desalting for Liquid Chromatography–Tandem Mass Spectrometry Analysis Using Beckman Coulter Biomek i7 Hybrid Workstation
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Соответствие требованиям GMP
- Getting Started with Kaluza: Data Scaling and Compensation Adjustment
- Getting Started with Kaluza: Parameters
- Система адаптеров g-Max предоставляет новые возможности при работе на ультрацентрифугах Beckman Coulter
- A method of grading nanoparticles using ultracentrifugation in order to determine the accurate particle diameter
- Compensation Setup For High Content DURAClone Reagents
- HIAC Industrial – Our overview solution for fluid power testing for all applications
- High throughput cultivation of the cellulolytic fungus Trichoderma reesei in the BioLector®
- High-Throughput qPCR and RT-qPCR Workflows Enabled by Echo Acoustic Liquid Handling and NEB Luna Reagents
- A Highly Consistent BCA Assay on Biomek i-Series
- A Highly Consistent Bradford Assay on Biomek i-Series
- A Highly Consistent Lowry Method on Biomek i-Series
- Highly Reproducible Automated Proteomics Sample Preparation on Biomek i-Series
- High-throughput IgG quantitation platform for clone screening during drug discovery and development
- High-throughput Miniaturization of Cytochrome P450 Time-dependent Inhibition Screening Using the Echo 525 Liquid Handler
- Cell Line Development – Hit Picking
- Host Cell Residual DNA Testing in Reduced Volume qPCR Reactions Using Acoustic Liquid Handling
- Exosome-Depleted FBS Using Beckman Coulter Centrifugation: The cost-effective, Consistent choice
- How Violet Side Scatter Enables Nanoparticle Detection
- Automating the Cell Line Development Workflow
- ICH Q2 – the Challenge of Measuring Total Organic Carbon in Modern Pharmaceutical Water Systems
- ICH Q2 – The Challenge of Measuring Total Organic Carbon in Modern Pharmaceutical Water Systems
- ICH Q2 – the Challenge of Measuring Total Organic Carbon in Modern Pharmaceutical Water Systems
- Illumina Nextera Flex for Enrichment on the Biomek i7 Hybrid Genomics Workstation
- Importance of TOC measurement in WFI in light of European Pharmacopoeia change
- Improved data quality of plate-based IgG quantification using Spark®’s enhanced optics
- Increased throughput for IgG quantification using Valita Titer 384-well plates
- Integration of the Vi-CELL BLU Cell Viability Analyzer into the Sartorius Ambr® 250 High Throughput for automated determination of cell concentration and viability
- Temperature dependence of hydrodynamic radius of an intrinsically disordered protein measured in the Optima AUC analytical ultracentrifuge.
- Introducing the Cydem VT System: A high-throughput platform for fast and reliable clone screening in CLD
- Issues with Testing Jet Fuels for Contamination
- Jurkat Cell Analyses Using the Vi-CELL BLU Cell Viability Analyzer
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Линейность результатов изучения олигомеризации БСА методом AUC с использованием оптики поглощения и интерференции
- Long Life Lasers
- LS 13 320 XR: Sample Preparation - How to measure success
- Beckman’s LS 13 320 XR Vs. Malvern Mastersizer
- Алгоритмы машинного обучения обеспечивают глубокое понимание состава клеточных субпопуляций при использовании 20-цветного иммунофенотипирования
- Matching Cell Counts between Vi–CELL XR and Vi–CELL BLU
- Media optimization in the RoboLector platform for enhanced protein production using C. glutamicum
- MET ONE 3400+ LDAP & Active Directory connection Guide
- Method for Determining Cell Type Parameter Adjustment to Match Legacy Vi CELL XR
- Migration of Panels Designed on the CytoFLEX S Flow Cytometer to CytoFLEX SRT Cell Sorter
- Miniaturization of an Epigenetic AlphaLISA Assay with the Echo Liquid Handler and the BMG LABTECH PHERAstar FS
- Miniaturization and Rapid Processing of TXTL Reactions Using Acoustic Liquid Handling
- Miniaturized Enzo Life Sciences HDAC1 Fluor de Lys Assays Using an Echo Liquid Handler Integrated in an Access Laboratory Workstation
- Miniaturized Enzymatic Assays with Glycerol
- Miniaturized EPIgeneous HTRF Assays Using the Echo Liquid Handler
- Miniaturized Gene Expression in as Little as 250 nL
- Miniaturized Genotyping Reactions Using the Echo Liquid Handler
- Miniaturized Multi-Piece DNA Assembly Using the Echo 525 Liquid Handler
- Miniaturized Sequencing Workflows for Microbiome and Metagenomic Studies
- Minimizing process variability in the manufacturing of bottled drinking water
- Mixed Mode Sorting on the CytoFLEX SRT
- Mode of operation of optical sensors for dissolved oxygen and pH value
- Modular DNA Assembly of PIK3CA Using Acoustic Liquid Transfer in Nanoliter Volumes
- Многоволновое аналитическое ультрацентрифугирование человеческого сывороточного альбумина, образующего комплекс с порфирином
- Nanoliter Scale DNA Assembly Utilizing the NEBuilder HiFi Cloning Kit with the Echo 525 Liquid Handler
- Nanoscale Sorting with the CytoFLEX SRT Cell Sorter
- What to do now that ACFTD is discontinued
- Low-pH profiling in µL-scale to optimize protein production in H. polymorpha using the BioLector
- Optimized NGS Library Preparation with Acoustic Liquid Handling
- Particle Counting in Mining Applications
- Performance of the Valita Aggregation Pure assay vs HPLC-SEC
- Phototrophic cultivation of Chlorella vulgaris in the BioLector XT microbioreactor
- Plate Deposition Speed Comparison of Astrios and CytoFLEX SRT Cell Sorters
- Precision measurement of adipocyte size with Multisizer4e
- Принципы проточного центрифугирования
- Flow Cytometric Approach to Probiotic Cell Counting and Analysis
- Protocols for use of SuperNova v428 conjugated antibodies in a variety of flow cytometry applications
- Purifying High Quality Exosomes using Ultracentrifugation
- Purifying viral vector with VTi 90 rotor and CsCl DGUC
- JP SDBS Validation
- USP System Suitability
- Calibrating the QbD1200+ TOC Analyzer
- Quality Control of Anti-Blocking Powder Particle Size
- Using the Coulter Principle to Quantify Particles in an Electrolytic Solution for Copper Acid Plating
- A Rapid Flow Cytometry Data Analysis Workflow Using Machine Learning- Assisted Analysis to Facilitate Identifying Treatment- Induced Changes
- Rapid Measurement of IgG Using Fluorescence Polarization
- Rapid Rabbit IgG Quantification using the Valita Titer Assay
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Root Cause Investigations for Pharmaceutical Water Systems
- Screening yeast extract to improve biomass production in acetic acid bacteria starter culture
- Single Cell Sorting with CytoFLEX SRT Cell Sorter
- Unveiling the Hidden Signals: Overcoming Autofluorescence in Spectral Flow Cytometry Analysis
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Specification Comparison of Vi–CELL XR and Vi–CELL BLU
- Spectral Flow Cytometry: A Detailed Scientific Overview
- Specifying Non-Viable Particle Monitoring for Aseptic Processing
- A Standardized, Automated Approach For Exosome Isolation And Characterization Using Beckman Coulter Instrumentation
- Streamlined Synthetic Biology with Acoustic Liquid Handling
- Switching from Oil Testing to Water and back using the HIAC 8011+ and HIAC PODS+
- SWOFF The unrecognized yet indispensable sibling of FMO
- Advanced analysis of human T cell subsets on the CytoFLEX flow cytometer using a 13 color tube-based DURAClone dry reagent
- The scattered light signal: Calibration of biomass
- Comparative Performance Analysis of CHO and HEK Cells Using Vi-CELL BLU Analyzer and Roche Cedex® HiRes Analyzer
- Using k-Factor to Compare Rotor Efficiency
- Utilization of the MicroClime Environmental Lid to Reduce Edge Effects in a Cell-based Proliferation Assay
- Validation of On-line Total Organic Carbon Analysers for Release Testing Using ICH Q2
- Vaporized Hydrogen Peroxide Decontamination of Vi–CELL BLU Instrument
- Vertical Rotor Case Study with Adenovirus
- Vesicle Flow Cytometry with the CytoFLEX
- Automating the Valita Titer IgG Quantification Assay on a Biomek i-Series Liquid Handling System
- Evaluating Clone Performance and Cell-Specific Productivity: Comparing the Cydem VT System and 10 L Bioreactor Cultivations
- Rapid, Automated Purification of Adeno-Associated Virus using the OptiMATE Gradient Maker
- Reducing Variability and Hands-On time in Viral Vector purification using the OptiMATE Gradient Maker
- Variability Analysis of the Vi-CELL BLU Cell Viability Analyzer against 3 Automated Cell Counting Devices and the Manual Method
- Automating the Valita Aggregation Pure Assay on a Biomek i-Series Liquid Handler
- Vi-CELL BLU FAST Mode Option
- Vi-CELL BLU Regulatory Compliance - 21 CFR Part 11
- Viral Vector Purification with Ultracentrifugation
- Analytical Ultracentrifugation (AUC) for Characterization of Lipid Nanoparticles (LNPs): A Comprehensive Review
- Whole Genome Sequencing of Microbial Communities for Scaling Microbiome and Metagenomic Studies Using the Echo 525 Liquid Handler and CosmosID
- Sorting Rare E-SLAM Hematopoietic Stem Cells Using CytoFLEX SRT and Subsequent Culture
- Unlocking Insights: The Vital Role of Unmixing Algorithms in Spectral Flow Cytometry
- Leveraging Analytical Ultracentrifugation for Comprehensive Characterization of Lipid Nanoparticles in Drug Delivery Systems
- Каталоги
- Experimental Protocols
-
Брошюры, буклеты и проспекты
- Access Single Robot System for Synthetic Biology Workflows
- Automated Solutions for Cell Line Development
- Automated Solutions for ELISA
- Echo Acoustic Liquid Handling for Synthetic Biology
- HIAC 8011+ Liquid Particle Counting Systems
- LS 13 320 XR - Laser Diffraction Particle Size Analyzer
- Download the Valita Titer Assay Brochure
-
Практические примеры
- Achieving Increased Efficiency and Accuracy in Clinical Testing
- Algae Biofuel Production
- Adenoviral Vectors Preparation
- Antibody and Media Development
- Choosing a Tabletop Centrifuge
- DNA Extraction from FFPE Tissue
- English Safety Seminar
- Equipment Management
- Exosome Purification Separation
- Fast, Cost-Effective and High-Throughput Solutions for DNA Assembly
- High-throughput next-generation DNA sequencing of SARS-CoV-2 enabled by the Echo 525 Liquid Handler
- Leveraging acoustic and tip-based liquid handling to increase throughput of SARS-CoV-2 genome sequencing
- Membrane Protein Purification X Ray Crystallography
- Organelles Simple Fractionation
- Sedimentary Geology
- Tierra Biosciences reveals major molecular discovery
- University Equipment Management
- Autophagy
- B Cell Research
- Basic Research on Reproductive Biology
- Cardiovascular Disease Research
- Cell Marker Analysis
- Collagen Disease Treatment
- Contribute To Society By FCM
- Controlling Immune Response
- Creating Therapeutic Agents
- DxFLEX that provides On-site Service Support
- Future of Fishing Immune Research
- Hematopoietic Tumor Cells
- Hiroshima Genbaku HP Hematopoietic Tumor Testing
- Improving Efficiency in Clinical FCM Workflow
- Looking to the Future of Research Support
- Opening New Possibilities for Extracellular Protein Degradation
- The Importance of FCM education and CytoFLEX
- Nanoflowcytometry for EV research
- iPS Cell Research
- Measuring the number of CD34 using AQUIOS
- Particle Interaction
- Quality evaluation of gene therapy vector
- Retinal Cell Regeneration
- Severe Liver Disease Treatment
- Treating Cirrhosis
- Fundamentals of Ultracentrifugal Virus Purification
- Буклеты
-
Интервью
- Background and Current Status of the Introduction of Flow Cytometers
- Bacteriological-measurements-of-soil-bacteria-in-paddy-fields
- Benefits-of-the-coulter-principle-in-the-manufacturing-for-ips-cell-derived-natural-killer-cells
- Breakthrough Solutions for Accurate Microbial Volume and Cell Count Measurement
- Fundamentals of Ultracentrifugal Virus Purification
- Central Diagnosis in the Treatment of Childhood Leukemia 1
- Central Diagnosis in the Treatment of Childhood Leukemia 2
- Challenges-in-viability-cell-counting
- Contribution of Cytobank to 1-cell analysis of the cancer microenvironment
- Development of technology for social implementation of synthetic biology
- Flow Cytometry Testing in Hospital Laboratories
- Принципы очистки вирусов методом ультрацентрифугирования
- Tumor Suppressor Gene p53 research and DNA Cleanup Process
- Dr Yabui UCF Lecture
- Importance of Cell Cluster Volume Measurement in Regenerative Medicine
-
Постеры
- Applications of Ultracentrifugation in Purification and Characterization of Biomolecules
- Automating Genomic DNA Extraction from Whole Blood and Serum with GenFind V3 on the Biomek i7 Hybrid Genomic Workstation
- ABRF 2019: Automated Genomic DNA Extraction from Large Volume Whole Blood
- Automated library preparation for the MCI Advantage Cancer Panel at Miami Cancer Institute utilizing the Beckman Coulter Biomek i5 Span-8 NGS Workstation
- Automating Cell Line Development for Biologics
- Cell-Line Engeneering
- Characterizing the Light-Scatter Sensitivity of the CytoFLEX Flow Cytometer
- AACR 2019: Isolation and Separation of DNA and RNA from a Single Tissue or Cell Culture Sample
- Mastering Cell Counting
- Preparing a CytoFLEX for Nanoscale Flow Cytometry
- A Prototype CytoFLEX for High-Sensitivity, Multiparametric Nanoparticle Analysis
- ABRF 2019: Simultaneous DNA and RNA Extraction from Formalin-Fixed Paraffin Embedded (FFPE) Tissue
- Quantification of AAV Capsid Loading Fractions: A Comparative Study
- Using Standardized Dry Antibody Panels for Flow Cytometry in Response to SARS-CoV2 Infection
- Пошаговые руководства
-
Публикации
- Algorithmic Tools for CytoFLEX mosaic Spectral Flow Cytometer
- Комплексное решение для очистки белка и количественного определения агрегации методом центрифугирования
- AUC Insights - Analysis of Protein-Protein-Interactions by Analytical Ultracentrifugation
- A General Guide to Lipid Nanoparticles
- Analytical Ultracentrifugation: A Versatile and Valuable Technique for Macromolecular Characterization
- Addressing issues in purification and QC of Viral Vectors
- Automation Approach to Accelerate Antibody Drug Development
- Elevate Your Extracellular Vesicle (EV) Research – An Introduction to EVs
- Enhancing Molecular Studies with Multiwavelength Analytical Ultracentrifugation
- GMP Cleanrooms Classification and Routine Environmental Monitoring
- Purification of Biomolecules by DGUC
- Качественный анализ аденоассоциированных вирусных векторов для генной терапии методом скоростной седиментации
- AUC Insights - Sample concentration in the Analytical Ultracentrifuge AUC and the relevance of AUC data for the mass of complexes, aggregation content and association constants
- Analyzing Biological Systems with Flow Cytometry
- Changes to USP <1788> Subvisible Particulate Matter
- Characterization of RNAdvance Viral XP RNA Extraction Kit using AccuPlex™ SARS–CoV–2 Reference Material Kit
- CytoFLEX Platform Gain Independent Compensation Enables New Workflows
- CytoFLEX Platform Flow Cytometers with IR Laser Configurations: Considerations for Red Emitting Dyes
- Evaluation of the Analytical Performance of the AQUIOS CL Flow Cytometer in a Multi-Center Study
- Simultaneous Isolation and Parallel Analysis of gDNA and total RNA for Gene Therapy
- Hydraulic Particle Counter Sample Preparation
- Inactivation of COVID–19 Disease Virus SARS–CoV–2 with Beckman Coulter Viral RNA Extraction Lysis Buffers
- Tips for Cell Sorting
- Liquid Biopsy Cancer Biomarkers – Current Status, Future Directions
- MET ONE 3400+ IT Implementation Guide
- Reproducibility in Flow Cytometry
- SuperNova v428: новый яркий полимерный краситель для проточной цитометрии
- SuperNova v428: новый яркий полимерный краситель для проточной цитометрии
- Japan Document
-
Указания по применению
-
Видео
-
Видео о продукции
- Access Laboratory Workstation Introduction
- Allegra V-15R Features and Benefits
- Allegra V-15R Launch Event
- Как работает проточный цитометр AQUIOS CL
- AQUIOS Designer Software Workflow Efficiency
- Онлайн-презентация проточного цитометра AQUIOS CL
- Automated Positive-Pressure Extraction: Biomek i-Series Integrated Solutions
- BeckmanConnect Privacy and Security Highlights
- BioLector XT Microbioreactor
- BioLector XT Microbioreactor & Biomek i5 Liquid Handler Integration
- Biomek i-Series and Echo Acoustic Liquid Handler Integrated Workstation
- Biomek i Series: Dual Gripping on the i7 Hybrid
- Biomek i Series: Gripper Rotation and Navigation on High-Density Deck
- Biomek i Series: Intrawell Pipetting for Mixing Using 96 Multichannel
- Biomek i Series: Parallel Processing on the i7 Hybrid
- Biomek i Series: Transferring Labware In/Out of an on-deck Automated Thermal Cycler (ATC)
- Biomek i5 for Automating Protein Quantification & Characterization
- Biomek i5 for Automating Screening & Hit Picking
- Biomek i-Series: 6-Column Multichannel Plate Transfer
- Biomek i-Series: 96 Multichannel Selective Tip Pipetting by Row and by Column
- Biomek i-Series: 96 Multichannel Tip Loading
- Biomek i-Series: Large Volume Transfer Using the 96 Multichannel
- CellMek SPS Innovation Keynote
- CellMek SPS Overview
- CellMek SPS Workflow
- Cydem VT Automated Clone Screening System
- CytExpert Compensation Workflow
- Overview of Cytobank Features and Functions
- Краткое знакомство с проточным цитометром DxFLEX
- Echo Liquid Handler Can Simultaneously Normalize and Pool NGS Library
- Echo Reduce Time in NGS
- Fully Automated Clone Selection: Biomek i-Series Integrated Solutions
- History of Automation
- Преимущество фотодетекторов, используемых в проточном цитометре DxFLEX
- Introduction to AUC_JP
- Introducing the QbD1200 TOC Analyzer
- MET ONE 3400+ Series Airborne Particle Counter
- MET ONE 3400+ Series Airborne Particle Counter
- Microtiter plate lid management
- OptiMATE Gradient Maker
- OptiMATE Gradient Maker Features
- OptiXTRACT Sample Recovery Aid
- Photodetectors in Flow Cytometry
- QbD1200 Virtual Demo of Calibration
- QbD1200 Virtual Demo of Paperless Reporting
- QbD1200 Virtual Demo of a Measurement Setup
- Reagent Kits for Viral RNA Extraction
- Span-8 1 mL tip loading
- Valita Titer Intro
- VD-016a-flow
- VD-031a-flow
- VD-032a-flow
- VD-033a-flow
- VD-035a-flow
- VD-048a-auto
- VD-057a-flow
- VD-060a-part
- VD-067a-cent
- VD-068a-cent
- VD-081a-auto
- VD-091a-part
- VD-093a-auto
- VD-095a-flow
- VD-098a-part
- VD-123a-cent
- VD-144a-auto
- VD-145a-auto
- VD-146a-auto
- VD-151a-auto
- VD-163a-flow
- VD-168a-flow
- VD-179a-flow
- VD-180a-flow
- VD-186a-flow
- VD-187a-flow
- VD-188a-flow
- VD-189a-flow
- VD-190a-flow
- VD-191a-flow
- VD-192a-flow
- VD-193a-flow
- VD-194a-flow
- VD-195a-flow
- VD-196a-flow
- VD-197a-flow
- VD-199a-auto
- VD-200a-auto
- VD-201a-auto
- VD-202a-auto
- VD-203a-auto
- VD-204a-part
- VD-205a-part
- VD-206a-part
- VD-207a-part
- VD-208a-part
- VD-209a-part
- VD-210a-part
- VD-211a-part
- VD-212a-part
- VD-213a-part
- VD-214a-part
- VD-215a-part
- VD-216a-part
- VD-217a-part
- VD-218a-part
- VD-219a-part
- VD-220a-part
- VD-221a-part
- VD-222a-part
- VD-237a-auto
- VD-239a-part
- VD-241a-auto
- VD-242a-auto
- VD-250a-cent
- VD-251a-cent
- VD-252a-cent
- VD-253a-cent
- VD-254a-cent
- VD-255a-cent
- VD-256a-cent
- VD-257a-cent
- VD-258a-cent
- VD-259a-cent
- VD-275a-cent
- VD-292a-part
- VD-293a-part
- VD-294a-part
- VD-297a-auto-ruo-ex-2021
- VD-301a-cent
- VD-302a-cent
- VD-303a-cent
- VD-309a-auto
- VD-313a-auto
- Vi-CELL BLU Analyzer Integration with Sartorius Ambr® 250 High Throughput Bioreactor & Ambr ® 15 Cell Culture Systems
- Vi-Cell BLU Sample Flow
- Introducing the Vi-CELL MetaFLEX
- DURA Innovations: A Better Monday
- Advantages of ClearLLab LS
- Allegra General Purpose Centrifuge Line
- Allegra X-15R - Aerosolve Package
- Allegra X-15R Centrifuge Performance
- AQUIOS CL Flow Cytometer Analysis and Reporting
- AQUIOS CL Flow Cytometer Automated and Single Loading
- AQUIOS CL Flow Cytometer Pipeline Sample Processing
- AQUIOS CL Flow Cytometer Sample Preparation
- AQUIOS CL Flow Cytometer Smart Track Reagent Monitoring
- AQUIOS CL Flow Cytometry Workflow Efficiency
- Automate Flow Cytometry Assays
- Avanti J-26S Performance
- Avanti J-26S Portfolio
- Avanti J-26S Redesign Advantages
- Avanti J-26S Safety and Reliability
- Avanti J-26S Sustainability
- Avanti J-26S User Experience
- Avanti J-26S Versatility
- Avanti JXN High Performance Centrifuge - Bioproduction
- Avanti JXN High Performance Centrifuge -- Manual Run
- Avanti JXN Series High Performance Centrifuge: Introduction
- Avanti JXN Series High Performance Centrifuges in Shared Labs
- Avanti JXN-26 High Performance Centrifuge
- Biomek 4000 Automated Workstation Overview
- Centrifuge Service Installation
- ClearLLab 10C System for Integrated L&L Immunophenotyping
- Offline analysis of CytExpert files using Kaluza Analysis Software
- Bandpass filter light path of the CytoFLEX
- Wavelength Division Multiplexer of the CytoFLEX
- CytoFLEX Lasers and Integrated Optics
- CytoFLEX LX Введение
- Peristaltic Pump in the CytoFLEX
- CytoFLEX Flow Cytometer Plate Loader Option Overview
- CytoFLEX flow cytometry for the bench (and other fun locales)
- CytoFLEX Flow Cytometer Special Procedure
- DURA Innovation Workflow Comparison
- DURA Innovations Technology and Advantages
- DxFLEX Overview
- Ease of Use Avanti JXN - High Performance Centrifuges
- Harvest Line System Liner: How to Use
- Harvest Line System Liner: How to Use
- HIAC 8011+ Digital Exports and Web Server
- HIAC 8011+ Liquid Particle Counter Features
- HIAC 8011 Plus Interchangeable Sensors and Magnetic Stirrer
- HIAC 8011+ Liquid Particle Counter Overview
- HIAC 8011+ Product Demonstration
- HIAC 8011+ Liquid Particle Counter Sample Recipe Setup
- 8011+ Sample Recipe Wizard
- HIAC 8011+ Self-Diagnostic Alerts and Cleaning Routines
- HIAC 8011+ Vacuum and Degas
- HIAC PODS+ Digital Exports
- HIAC PODS+ Filter Cart Mode
- HIAC PODS+ Internal Compressor and Moisture Detector
- HIAC PODS+ Online Mode
- HIAC PODS+ Liquid Particle Counter -- An Overview
- HIAC PODS+ Product Demonstration
- HIAC PODS+ Sample Recipe Wizard
- HIAC PODS+ Self-Diagnostic Alerts and Cleaning Routines
- Introducing the Biomek i-Series Automated Workstation
- Introducing the LS 13 320 XR
- Introduction to AUC - an Analytical Ultracentrifuge
- Introduction to CytoFLEX LX
- Kaluza Reads FCS Compliant Files: FACSCelesta
- Kaluza Reads FCS Files: FACSVerse Acquisition Data
- Kaluza Software Award
- Kaluza Software Design
- Kaluza Software Launch
- Kaluza Software Parametric Visualization
- Kaluza Software Performance
- LS 13 320 Overview - Particle Characterization
- LS 13 320 XR ADAPT Software
- LS 13 320 XR: X-D Array and PIDS Technology
- Changing the Module in the LS 13 320 XR
- Multisizer 4e Cell Counter and Analyzer -- An Overview
- Searching for the Oldest Centrifuge
- Optima AUC Overview, New Analytical Ultracentrifuge
- Optima MAX Series - Tabletop Ultracentrifuge
- Optima X Series Ultracentrifuges - An Overview
- Optima XE and XPN Ultracentrifuge Performance
- Optima XE and XPN Safety and Reliability
- Optima XE and XPN Ultracentrifuges: A Total System
- Оптимизация контроля качества фармацевтической продукции
- Results with Tandem Dyes
- The AQUIOS CL Flow Cytometer Advantage
- The History of AUC - An Analytical Ultracentrifuge
- Ultra Harmonic Technology in the Avanti J-15 Centrifuge
- Unboxing Your New CytoFLEX Flow Cytometer
- Vi-CELL BLU Livestream Announcement
- Vi-CELL BLU Product Launch
-
Scientific Videos
- The Coulter Principle
- Overview of Density Gradient Equilibrium Analytical Ultracentrifugation (DGE-AUC)
- 3D Imaging of Cancer Spheroids
- A Simplified Approach to Automating ELISA
- Advances in Cellular Automation
- Advances in Synthetic Biology Technologies: Cell-Free Protein Synthesis from Academia to Applied Market
- Automated 3D Cell Culture and Screening by Imaging and Flow Cytometry
- Automated Cell Culture Workflows: Biomek Integrated Solutions
- Automated group testing at scale to enable COVID-19 decision makers - Using Echo for tapestry pooling and high-throughput qPCR setup
- Avalanche Photodiodes in CytoFLEX
- Biomek FXP as a tool for discovery
- CAR-T Cell Therapy: Introduction and Overview
- Cellular Solutions of all Shapes and Sizes
- Centrifuge 101
- Challenging Samples in Cancer Research: Formalin-Fixed Paraffin-Embedded Tissues
- Contract Manufacturing Services
- CRISPR for Immunotherapy: Introduction and Overview
- Custom Design Services for Multi-Color Flow Cytometry
- Cytogenetics Cancer Research
- Digital Pathology Image Analysis for Cancer Research
- DNA and RNA Sequencing Sample Preparation
- DURAClone Technology
- Echo Acoustic Liquid Handling Technology
- ELISA Automation on a Biomek i-Series
- An Overview of Exosome Isolation
- The Principle of Flow Cytometry (FCM)
- Flow Cytometric Analysis of Hematologic Malignancies with ClearLLab LS Tube
- Gene Therapy Workflow from Production to Quality Control
- Automated human stem cell-based phenotypic high-throughput drug screening
- How Automation Helps to Improve your ELISA
- Immunotherapy Introduction and Overview
- New Automation Strategies for Improving Sample Prep for The Analytical Laboratory
- Increasing NGS Sequencing Capacity with High-Throughput Automated TruSeq Stranded mRNA Library Construction
- Industrial Fluid Particle Counter Sample Preparation
- Innovation to Improve Genomic Sample Prep
- Introduction to Automating NGS Workflows
- Introduction to Flow Cytometry
- Multipurpose robotic platform for molecular biology, biophysical, and cellular assays
- NanoGBS - A Miniaturized Procedure for Genotyping By Sequencing Library Preparation
- Automated NEBNext Ultra Directional RNA Library Prep Kit
- Phospho Epitopes Exposure Kit
- Proteome Centric Precision Medicine - Embracing Pathological Diversity
- Evaluation to Implementation with the University of Luxembourg
- Sample Preparation for Biologics Bioanalysis
- Chemogenomics - Screening of Biologically Active Drug Libraries
- Small Talk: Episode 1 - Before You Even Start…
- Small Talk Episode 2 - Harvesting EVs
- Small Talk: Episode 3 - Getting Ready for Your Experiment
- Small Talk Episode 4 - Let's Explore
- Small Talk Episode 5 - The Power of Flow
- Small Talk Q&A
- SPRI Bead Technology Video
- A Streamlined Approach to Automating ELISA
- Cell volume is an important indicator of white blood cell health and therapeutic potential
- Translating Nature into Medicine Using Machine Learning, Metabolomics, and High-Throughput Pharmacology
- Unlocking FFPE Tissues using Illumina NGS Biomek Automated Sample Preparation
- VersaComp Antibody Capture Beads
- Viral Particle Production 101
- Viral Vectors Introduction and Overview
- Workflow Challenges Solved: The Palmer Lab
-
Symposium Videos
- Assessing Proliferation and Cytotxic Potential Using Multicolor Flow Cytometry
- AUC Symposium: Characterization of Gene Therapy Formulations by Analytical Ultracentrifugation
- AUC Symposium - Building Better Things with the Analytical Ultracentrifuge
- Lipid Nanoparticles: Paradigm-Shifting Nucleic Acid Therapeutics
- AUC Symposium Panel Discussion - June 2021
- Analytical Ultracentrifuge (AUC) Symposium Series: Multiwavelength Analysis of Proteins (Session 1)
- Analytical Ultracentrifuge (AUC) Symposium Series: Multiwavelength Analysis of Proteins (Session 2)
- Automation of sample preparation for an efficient protein quantification workflow for proteomics
- Covid Symposium Day1, Q&A, Panel Discussion
- Anis Larbi Physiological Aging and Immunological Erosion
- Andrea Cossarizza Recognizing the Immune Response to SARS-CoV-2
- Ryan Brinkman The COVID Cytometry Project
- Q & A Session from Day 2, Viral Particle Detection and Characterization
- Silvana Verdiani New ELISA Kit for Serological Testing for SARS COV-2 Infection
- Miranda Byrne-Steele A Needle in a Haystack Using Immune Repertoire and Single Cell VDJ Sequencing to Identify COVID-specific B-cell Responses
- Marc-Andre Langlois Learnings from Single Particle Analysis of Moloney MLV Insight into its Infectivity, Genome Packaging Efficiency, and Host Marker Acquisition
- Q & A Session from Day 3, Vaccine and Therapy Development
- Jean Boyer Development and Immune Assessment of a DNA Vaccine Against COVID-19
- Bernhard Ellinger Using drug repurposing to identify inhibitors of SARS-CoV-2 cellular toxicity in vitro
- Bruce Patterson Disruption of the CCL5RANTES-CCR5 Pathway 1 Restores Immune Homeostasis and Reduces Plasma Viral Load in Critical COVID-19
- DKMS Life Science Lab: ultra-high throughput HLA genotyping for stem cell donor recruitment
- Extracellular Vesicles for ‘Liquid Biopsy’ Development in Cancer by Dr. Karla Williams
- Introduction to Mesenchymal Stem Cell DURAClone Dry Reagents
- Miniaturization of metagenomic RNA-seq library prep demonstrates greatly improved productivity and efficiency when utilizing acoustic liquid handling
- Miniaturized Illumina Nextera XT Library Prep using an Integrated Biomek i5 and Echo 525 Liquid Handling Workstation
- Monitoring Signal Transduction Pathways in Human Disease
- Multi-Sizing your Multi-Color Panel
- SynBioBeta 2020 with Beckman Coulter Life Sciences
-
Видеоотзывы
- Allegra V-15R Testimonial by Dr. Martin J. Richer
- Analytical ultracentrifugation - hear it from our customers
- Отзыв о проточном цитометре AQUIOS CL от сотрудников Университета Майами
- Mobile Lab with AQUIOS - Dr Lillian Hesselink
- Mobile Lab with AQUIOS - Dr Roy Spijkerman
- A moment analytical ultracentrifugation gave you an answer that made you really happy
- BeckmanConnect Tohoku University
- Collaborative data analysis platform explained by our expert Herve Luche
- CytoFLEX Testimonial Dr Karen Hogg University of York
- Discovery in Motion: High-throughput Automation Solutions at Sintef
- Sintef: Why a CRO Chooses to Automate their Lab with Biomek Liquid Handlers
- Using Vertical Rotors and the new VTi 50.1 by Chris Nieder
- Dr. Karla Williams on Analyzing Extracellular Vesicles Using the CytoFLEX
- Reflections on 70 Years of Centrifugation Innovation
- Exosomes Workflow Testimonial with Dr. Vannberg
- Flow Cytometry Collaboration with Dr Karen Hogg
- Dr. Jurgen Riedl, Clinical Chemist, Albert Schweitzer Hospital Customer Testimonial
- Customer Testimonial: Flow Cytometry Service and Support with Dr. Karen Hogg
- Selecting High Performance Flow Cytometry Reagents with Dr. Karen Hogg
- High Quality Flow Cytometry Reagent Selection Criteria with Dr. Karen Hogg
- Видеотзыв Д-ра Борриса Демелера: "Новый уровень простоты AUC анализа"
- AQUIOS CL Benefits with Casiana Fernandez-Bango
- AQUIOS CL Size Testimonial with Alexandra Amador
- AQUIOS CL Software Testimonial with Casiana Fernandez-Bango
- AQUIOS CL Training Testimonial with Alexandra Amador
- Sales to Implementation with the University of Luxembourg
- CytoFLEX Cancer Biology Research Testimonial with Leonardo Salmena
- CytoFLEX Capabilities Testimonial with Sarah Schuett
- CytoFLEX Lab Perspective Testimonial with Sarah Schuett
- CytoFLEX S Accelerated Research Testimonial with Brian Phillip
- CytoFLEX S Contest Winner Testimonial with Brian Phillip
- CytoFLEX S Potential Testimonial with Brian Phillip
- CytoFLEX Upgrades Testimonial with Sarah Schuett
- CytoFLEX Value Testimonial with Sarah Schuett
- Kaluza Software Testimonial with Dr. Rob Woestenenk
- Kaluza Software Testimonial with Tim Hutten
- Utilizing the CytoFLEX Testimonial with Leonardo Salmena
-
Training
- CytoFlex operation in Chinese
- AQUIOS CL Flow Cytometer - Advanced Operation Training
- AQUIOS CL Flow Cytometer - Advanced Operation Training in French
- AQUIOS CL Advanced Operation in German
- AQUIOS CL Advanced Operation in Italian
- AQUIOS CL Advanced Operation in Portuguese
- AQUIOS CL Flow Cytometer - Advanced Operation Training in Russian
- AQUIOS CL Advanced Operation in Spanish
- AQUIOS CL Flow Cytometer - Basic Operation Training
- AQUIOS CL Basic Operation in French
- AQUIOS CL Basic Operation in German
- AQUIOS CL Basic Operation in Italian
- AQUIOS CL Basic Operation in Portuguese
- AQUIOS CL Flow Cytometer - Basic Operation Training in Russian
- AQUIOS CL Basic Operation in Spanish
-
Tutorial Videos
- 5 Years of high-throughput strain engineering with the Echo: lessons from Zymergen Automation presented by Christopher Bremner, Automation Engineer, Zymergen @SLAS2020
- Characterization of CytoFLEX Gain Settings
- Cytobank Basics
- Cytobank CITRUS
- Cytobank Experiment Manager
- Cytobank FlowSOM
- Cytobank SPADE
- Cytobank viSNE
- Creating an Experiment using CytoFLEX
- Generating a Compensation Matrix using CytoFLEX
- CytoFLEX How to Set Up Violet Side Scatter
- How to Install Rotors on Allegra V-15R
- How to Program ECO Mode on Allegra V-15R
- How to Program Rapid Temp on Allegra V-15R
- How to Register Your Instrument with BeckmanConnect
- How to Set-Up and Run a Program on Allegra V-15R
- Intellifuge Calculator Introduction
- Kaluza Batch Analysis Tutorial with Dr. David Onion
- Kaluza Boolean Gates tutorial with Dr. David Onion
- Kaluza Cell Cycle Analysis Tutorial with Dr. David Onion
- Kaluza Composites Tutorial with Dr. David Onion
- Kaluza Cytobank Plugin
- Kaluza Linked Gates Tutorial with Dr. David Onion
- Kaluza Levey-Jennings Plots and Quality Control Analysis Tutorial with Dr. David Onion
- Kaluza Radar and Tree Plots Tutorial with Dr. David Onion
- Kaluza Tables and Export Tutorial with Dr. David Onion
- Off-the-shelf, Echo-based DNA Assembly Automation presented by George McArthur, Arzeda @SLAS2020
- Optima AUC Cell Assembly Tutorial
- Optima AUC Cell Loading Tutorial
- Optima AUC Cell Preparation Tutorial
- Seminar: Diverse Applications of Flow Cytometry to Answer Biological Questions
- Extended Features for Kaluza Software Tutorial
- Getting to Know Kaluza Acquisition Software Tutorial
- Seminar: High Dimensional Flow Cytometry on Small Instrument Platforms Tutorial
- Kaluza Analysis Overview Tutorial
- Kaluza for Gallios Compensation Worklist Tutorial
- Kaluza for Gallios Simulator with a Legacy Browser Tutorial
- Kaluza for Gallios Software Tutorial - Flow Cytometry
- Kaluza Analysis Software Tutorial - Loading Files and Creating Plots
- Kaluza Analysis Software: Creating Overlay Plots
- Setting up Statistics with Kaluza Software Tutorial
- How to Fill and Seal a Quick-Seal Tube
- How to Seal Quick-Seal Tubes using the Cordless Tube Topper
- How to Use Open-Top Tubes in Ultracentrifuges
- How to Fill and Plug a OptiSeal Tube
- Syringe Extraction of a Ultra-Clear, Quick-Seal Tube
-
Вебинары
- 21 CFR Part 11 for Particle QC Applications
- Addressing the Challenges of Purification & Quality Control in Gene Therapy
- Cell-Free Technology and Acoustic Liquid Handling Are Helping Tierra Disrupt Natural Product Discovery
- Characterizing Viruses: From Deadly Pathogens to the Workhorses of Gene Therapy
- Cytobank Webinar - CITRUS in Practice with Dr. Anna Belkina
- Clinical Flow Cytometry User Group Meeting
- Kaluza Batch Analysis Tutorial with Dr. David Onion
- Вебинар "Kaluza: Новые горизонты в анализе данных проточной цитометрии"
- Leveraging acoustic and tip-based liquid handling to increase SARS-CoV-2 sequencing throughput
- QbD1200+ Expert Roundtable
- Is Your Online TOC Analyzer Ready to Meet Pharmacopeia and Annex 1 Requirements?
- Субпопуляционный состав Т-лимфоцитов периферической крови человека – возможности 17-цветного анализа
- GMP Cleanroom Routine Environmental Monitoring & 21 CFR Part 11 Data Integrity
- ACFTD Discontinuance and the HIAC 8011+ and HIAC PODS+
- Achieving Cell-Free Gene Expression with An Acoustic Liquid Handler
- Seminar: Advanced Sensitivity and Resolution in Flow Cytometry through Innovation
- Достижения в области седиментационного анализа (докладчик: д-р Боррис Дэмлер (Borries Demeler))
- Agencourt AMPure XP
- Automated Alternative to the Hanging Drop Method of Stem Cell Differentiation
- An End-to-End Automated Workflow for High-Throughput SARS-Cov-2 Sequencing and Surveillance
- Webinar: An Intro to Characterization of Biomolecules Using AUC
- Analysis of Cell Biochemical Processes from First Principles to Cytometry
- Анализ гранулометрического состава с помощью аналитического ультрацентрифугирования
- Аналитическое ультрацентрифугирование для структурного анализа: белки и макромолекулярные комплексы
- Применение аналитического ультрацентрифугирования в биофармацевтической отрасли
- Применение аналитического ультрацентрифугирования для исследования наночастиц
- Аналитические методики количественного определения пустых и полных вирионов аденоассоциированного вируса
- Изучение углеродных нанотрубок с помощью метода AUC
- Практическое применение проточного элютриационного центрифугирования (CCE)
- Automated 3D Cell Culture and Screening by Imaging and Flow Cytometry
- Automated Assays For Protein Engineering, In Vitro And In Vivo, By Dr. Daniela Quaglia
- Automated High-Throughput and High-Content Analysis by Flow Cytometry
- Using Data to Drive Automated Screening and Effective Reporting
- Automating Continuous Cell Culture by Dr. Oliver Gassmann
- Taking the Tricky Out of Automating NGS Sample Prep
- Automation of PCR Setup and AMPure XP Purification using the Biomek 4000 Workstation
- Automation-Enabled LC-MS Analysis of Biologics
- Avoid Pitfalls When Automating Cell Viability Counting for Biopharmaceutical Quality Control
- Avoiding the Perils of Hidden Requirements
- Basic Research Signaling Applications
- Вебинар: Диагностика B-клеточных лимфопролиферативных заболеваний методом проточной цитометрии
- Использование метода AUC для характеризации систем доставки вирусных векторов
- Cell Counting & Viability: Faster Results Through Automation
- Cell Cycle Analysis by Quantitative Imaging Cytometry
- Cellular Analysis Using the Coulter Principle
- Centrifugal Elutriation - Utility in the Flow Cytometry Laboratory
- Centrifugation Safety 1 (Japanese)
- Centrifugation Safety 2
- Centrifugation Safety (Japanese)
- Changes to USP <1788>: Determination of Subvisible Particle Matter from the HIAC and Coulter Counters
- Changes to USP <643> Total Organic Carbon for Pharmaceutical Grade Waters
- Characterization of CRISPR Technologies Using Cell-Free Transcription and Translation and an Acoustic Liquid Handler
- Characterization of CRISPR Technologies Using Cell-Free Transcription and Translation and an Acoustic Liquid Handler
- Characterization of Extracellular Vesicles with Nanoscale Flow Cytometry
- Characterization of LNPs via Density Matching AUC
- Characterizing Viral Vector Fullness in Density Gradient Separations
- Cleanroom Routine Environmental Monitoring & Classification
- Contamination Control in the Hydraulic Industry
- Cytobank Bootcamp Session #6 Single Cell Data
- Cytobank Bootcamp Session #4 FlowSOM
- Cytobank Bootcamp Session #1 Introduction to Cytobank
- Cytobank Bootcamp Session #3 viSNE
- Cytobank Bootcamp Session #2 Data Management
- Cytobank Bootcamp Session #5 Biomarker discovery with CITRUS
- Machine Learning Assisted Population Identification
- Cytometry data sharing platform for collaborative multi-centric data analysis
- Data Insights for Automated Liquid Handling
- Сортировка дендритных клеток
- Способы детекции внеклеточных микрочастиц методом проточной цитометрии
- Development and Production of Viral Vectors: Advances in Processes and Translation for Human Gene Therapy
- Diamond-Based Nanomedicine for Enhanced Cancer Treatment and Imaging
- Direct EV Measurement in Complex Biofluids Using Single Vesicle Flow Cytometry (vFC) and the CytoFLEX
- Recent Advances in Immunotherapy: Directing Cells to Address Disease
- Diversity of Cancer-Derived Extracellular Vesicles
- Diversity of Extracellular Vesicles and Their Cargo in Cell-To-Cell Communication
- Вебинар ДНК-цитометрия
- Вебинар: Диагностика лекарственной аллергии методом проточной цитометрии
- Emitting Dye for Violet Laser Excitation with Krome Orange
- Evolution in the Manufacturing of Cellular Therapies
- Exosome Biogenesis and the Budding of Proteins and Viruses
- High-Performance Exosome Purification and Characterization via automated Density Gradient
- Exploring Exosomes and the Tumor Microenvironment
- Исследование стехиометрии макромолекулярных комплексов с использованием многоволнового анализа на аналитической ультрацентрифуге
- Extracellular Vesicle Isolation by Flow Cytometric Sorting and Characterization by Analytical Ultra-Centrifugation and Dynamic Light Scatter
- Extracellular Vesicles Delivery and RNA Translation
- Fast Cost-Effective High Throughput Solutions for DNA Assembly
- Advanced Flow Cytometric Analysis of Human T-Cell Memory Subsets
- Flow Cytometry Data Analysis in a Flash
- Проточная цитометрия в клинической иммунологии – современный подход к оценке иммунного статуса
- Fully Automated RNA Library Preparation for Sequencing Respiratory Viruses
- Gallios Flow Cytometer Forward Angle Light Scatter Innovation
- Goldilocks & the Three Cells: The Art of Monitoring & Managing Cell Cultures
- Hematopoietic Bone Marrow Cell Sorting without Compromise
- How Stem Cells Speak with Immune Cells
- ICH Q2 Validation of Analytical Procedures for Pharmaceutical TOC Analyzers
- Identifying and Isolating Stem Cells Through High-Speed Cell Sorting
- Is Immunotherapy Living up to its Promise?
- New Automation Strategies For Improving Sample Prep - The Analytical Laboratory
- Initial Evaluation of the ClearLLab 10C System in the Immunophenotyping of Leukemia and Non Hodgkin Lymphoma
- Isolation and Characterization of Exosomes and Ectosomes
- Isolation of Extracellular Vesicles: Latest Advances and Challenges
- Large Scale Purification of RNA and RNA-based Nanoparticles by Preparative Ultracentrifugation
- Laser Cytometry in Biomedical Analysis
- Вебинар: "Изучение популяционного состава лейкоцитов при COVID-19 методом проточной цитометрии"
- Leveraging the Value of Automated High-Content Screening
- Looking Under the Hood: Getting Started with the Optima AUC
- Cleanrooms: Controlling Contamination, Setting Alerts & Actions, Considerations of Removal Efficiency
- GMP Cleanroom Routine Environmental Monitoring & 21 CFR Part 11 Data Integrity
- Particle Monitoring Systems for Isolator / RABS Filling Lines and 503B Compounding Facilities
- Measuring Molecular Interactions by Multi-Wavelength AUC
- Microvesicle Detection and Cell Sorting
- On the Importance of Monitoring Both Transfection and Transduction Efficiencies in Cell Therapy Development
- Monitoring Signal Transduction Pathways in Human Disease
- Вебинар "Многоцветная цитометрия: от понимания к успеху"
- Multi-Color Solution for Flow Cytometry
- Combined Use of Multiple Particle Characterization Technologies to Evaluate Targeted Liposomal Formulations
- Multi-Sizing your Multi-Color for Panel Design
- Nano-Emulsion Formulation and Characterization Life Science and Industrial Markets
- Webinar: NanoGBS—A Miniaturized Procedure for Genotyping by Sequencing Library Preparation
- Next Generation Polymer Dyes: Enhance your multicolor flow cytometry panels
- Вебинар: "Приведение электронных записей в соответствие с 21 CFR Part 11"
- Advanced Process Quality Control and Outlier Detection with Discrete Particle Analysis
- Overcoming the Hurdles of Density Gradient Ultracentrifugation for Optimized Gene Therapy Purification Workflows
- Particle Counters Must Now be Calibrated With ISO 21501-4
- Гранулометрический анализ методом лазерной дифракции – предварительная оценка результатов
- Particle Size and Associated Sedimentary Processes on Wetland Gain and Loss in the Mississippi River Delta
- Particle Size Characterization by Laser Diffraction Analysis in Geoscience and Soil Science
- Particle Size Distribution for Cement using Laser Diffraction
- Total Organic Carbon Analysis in the new ASTM E3106 Cleaning Standard
- Physical and Chemical Characterization of Nanoparticle Constructs Using the Analytical Ultracentrifuge
- Изучение клеток растений методом проточной цитометрии
- Вебинар: Практические аспекты интерпретации результатов лазерной дифракции
- Predictive power of CITRUS
- Proteome Profiling of the Tumor Microenvironment: Role of Human Primary Fibroblasts Derived Exosomes in Oral Cancer Progression
- Quantifying Protein Aggregates by Sedimentation Velocity
- Quantitative Determination of Reaction Stoichiometry, Interaction Energies, and Solute Masses Using Analytical Ultracentrifugation
- Анализ редких событий методом цитометрии
- Rethinking Data Analysis for Flow Cytometry with Kaluza 1.1 Software
- Вебинар: «Обновленный стандарт ISO 14644-1: новое в классификации и методах мониторинга»
- Sample Prep for MS
- Вебинар: "Постковидные изменения состава T- и B-лимфоцитов и SARS-CoV-2-специфичный иммунитет"
- Scaling-Up Exosomes and Other Extracellular Vesicles
- Contemporary Cell Staining and Imaging Tools for Screening Stem Cell-Derived Cardiomyocytes
- Introduction to the New USP <787>: Subvisible Particulate Matter in Therapeutic Protein Injections
- Take the Risk out of Rotations Understanding and Implementing BioSafety Solutions in Centrifugation
- Testing Vaccines Final Form Dose to USP<787> Subvisible Particulate Matter
- The Art of Sorting for Advancing Cytometry
- The Complexities of SV Analytical Ultracentrifugation: AAVs are not Simple, Binary Systems
- The Future of Liquid Handling Automation has Arrived
- The Power of Automated Assay Optimization
- The Role of Exosomes in Inflammatory Disease - Pathogenesis and Treatment
- The Science of Flow Cytometry Part 1
- The Science of Flow Cytometry Part 2
- Three Distinct Analytical Ultracentrifugation Methods for Virus and Viral Vector Characterizations
- Transferring Cell Counting Methods: Best Practices
- Cross-talk and Developmental Programs - A Key to Translational Stem Cell Biology
- Understanding the How and the Why: Biosafety in Centrifugation
- Understanding the Role and Benefits of Centrifugation in Cell Harvest and Separation
- qPCR Webinar: Scalable Workflows for Viral RNA Extraction and Reaction Setup
-
Видео о продукции
-
Области применения продукции
- Use of Cells in Therapeutics Product Development
- Lead Optimization
- Контроль качества для производств GMP
- Echo Liquid Handling for ADME-Tox
-
Biologics Product Applications
- High-Throughput Screen (HTS)
- Liquid Handling for Gene Expression
- Liquid Handling for Genotyping
- Helping the Immune System Beat Cancer: Biologics in Immuno-oncology Research
- Liquid Handling for Microbial Research
- A Natural Answer: Biologics 101
- Natural Factories: Biologics Production 101
- Package Delivery: Biologics as Vectors
- Acoustic Liquid Handling for Protein Crystallography
- PCR, qPCR, and RT-qPCR
- Restoring Balance: Biologics in Immune-Disorder Research
- Решения для исследований COVID-19
- Echo Liquid Handling for Microsampling
- Multi-omics
- Process Development Manufacturing: Biotherapeutics
- Transcriptomics
-
Методы и инструменты
- Cell Harvest
-
Immunophenotyping
- アプリケーション
- Atoz
- Beginner
- Bioessay
- Campaign
- Efficient Operation of Flow Cytometer
- Центрифугирование
- Центрифугирование
- SDS Download
- Spectoral Flow Cytometry
- Streamline Clinical Workflow
- Catalog
- Cd Chart
- Cyto Story
- Cytometry
- Data
- Digitalfcm
- Epics1972
- Fcm
- Fcm First Time
- Fcm Yougo
- Fcmprinciple
- Pnh
- Practical Flow Cytometry
- Qc
- Reagent
- Sample Prep
- Sikisohyou
- Support and Service
- Typing
- Whats Cytometry
- Ведение клеточных культур
- Иммунологический мониторинг
- Interaction Quantification & Characterization Using Analytical Ultracentrifugation
- Высокопроизводительный скрининг
- Viral Particle Purification Using Centrifugation Methods
- Масс-спектрометрия
-
spINSIGHTS: о методе центрифугирования в деталях
- В чём разница между стерильными и Certified Free пробирками? Какая степень чистоты мне нужна?
- Why should I choose ultracentrifugation as the preferred method for extracellular vesicle purification?
- When should I choose centrifugation instead of affinity chromatography for purifying viral vectors?
- How can I develop a deeper understanding of my lipid nanoparticle heterogeneity?
- ELEVATING EV Characterization with Analytical Ultracentrifugation (AUC)
- How can I minimize potential sample waste when using the OptiMATE Gradient Maker to dispense gradients?
- Какие особенности позволяют аналитической ультрацентрифуге Optima AUC улучшать качество данных и эффективность экспериментов?
- Как адаптировать существующий протокол центрифугирования к новому ротору, флаконам или пробиркам?
- Почему метод аналитического ультрацентрифугирования (AUC) оптимален для характеризации аденоассоциированных вирусных векторов (AAV)?
- Как приготовить градиенты плотности, чтобы добиться воспроизводимости при очистке образцов методом ультрацентрифугирования?
- Can Sapphire windows be used for low-UV AUC experiments?
- Краткая информация о методе аналитического ультрацентрифугирования (AUC) и ультрацентрифуге Optima AUC
- How does data from AUC determine dose optimization in therapeutic liposomes?
- How can data from AUC help improve AAV Production Yield?
-
Immunophenotyping
- About Immunophenotyping
- Seven Tips for Achieving the Perfect Panel for Multicolor Flow Cytometry
- Speed up your setup: The CytoFLEX Platform and how to fast-track 20-color panel design
- Free Fluorochrome chart for easy panel design
- Panel Builder
- Panel Builder Resources
- Исследования в иммунотерапии: Оборудование
- Optimized Multicolor Immunophenotyping Panels (OMIPs) for Flow Cytometry
- Customer Testimonials
-
Научные направления
- 3D клеточные культуры
- Extracellular Vesicles
-
Контроль продвинутой стадии ВИЧ
- 12 Steps to CD4 Testing
- Advanced Disease Management
- World Health Organization Guidelines Reinforce Role of CD4 Cell Counting in Immunocompromised Patients
- CD4 Testing in Remote Areas
- Innovation In CD4 Testing
- The Impact of Laboratory Proficiency Testing And External Quality Assurance Schemes In Resource Limited Settings
- What is CD4 & Why is it Important?
- An Overview of the Current Status for the Global HIV/AIDS Pandemic
-
Small Particle
- Verifying for Small Particle with Certified Beads
- Исследования в иммунотерапии: Оборудование
- Characterization of Extracellular Vesicles with Nanoscale Flow Cytometry
- Measuring Single EVs and their Cargo: Sensitive and Specific Vesicle Flow Cytometry (vFCTM)
- Things to Consider for Small Particle Research
- Western Blot and Other Methods vs. Nanoscale Flow Cytometry
- About Biological Nanoparticles and Microparticles
- Easy to Learn: A New User CytoFLEX Experience
- A Discovery in the Williams Lab
- Trends in Extracellular Vesicle Research
- Free Extracellular Vesicles Poster For Your Lab
- Nanoscale Frequently Asked Questions
- Small Talk
- Karan's Story
- Astrios and the Nanoscale
- Cell Sorting at the Nano Scale
- The Importance of Guidelines in Small Particle Research
- How the CytoFLEX Enabled The Williams' Lab Extracellular Vesicles Research
- Machine Learning Assisted Analysis for Cytometry Data
-
Научные направления
Related Video: Cellular Analysis Using the Coulter Principle